Frequently asked questions
Extracellular Vesicle Biology
Extracellular vesicles (EVs) are nanoparticles produced by cells. EVs are enclosed by the same lipid bi-layer membrane as the cell from which they derive and contain lipids, proteins, and nucleic acids.
Extracellular vesicles (EVs) have been demonstrated to mediate intercellular communication, carrying cargo from one cell to another. EVs released from cells are then taken up by other cells, which may change their activity (or not) in response to the newly received information.
EVs are considered to have immense potential for improving human health in biomarker discovery, disease diagnosis and monitoring, and therapeutic cargo delivery.
Quantifying extracellular vesicles (EVs) is important for many different reasons. In research, it is often one of the first analyses a researcher will do to ensure the sample they are studying contains EVs in the quantity or concentration necessary to perform other analyses. In EV-based diagnostics development, diagnostics developers and manufacturers need to know how many EVs are present in a sample to determine the limits and linearity of the assay and for quality control to ensure the assay is performing according to specification. EV-based therapeutics developers and manufacturers need to know how many EVs are in a dose of the therapeutic to determine potency and dosing and for quality control to ensure the manufactured therapeutic meets the specification.
Measurement capabilities
EVsure deploys three pairs of tetraspanin-directed recombinant antibodies targeting CD9, CD63, and CD81 tetraspanins simultaneously, each carrying one half of a split luciferase enzyme particle. When two antibodies of the same specificity bind their target tetraspanin on the same intact EV surface, the luciferase fragments are brought into proximity and reconstitute enzymatic activity, resulting in luminescence. The luminescent reader reads the combined luminescent signals from all three antibody pairs to produce a single readout proportional to the total count of tetraspanin-positive EVs in the sample.
No, EVsure does not measure individual vesicles. EVsure measures the luminescence produced when antibodies of the same specificity bind their target tetraspanin on the same intact EV surface. The luminescent reader reads the combined luminescent signals to produce a single readout proportional to the total count of tetraspanin-positive EVs in the sample.
EVsure provides the combined concentration of CD9, CD63, and CD81 tetraspanin-positive EVs.
EVsure measures the combined concentration of CD9, CD63, and CD81 tetraspanin-positive EVs irrespective of size, biogenesis pathway, or other distinguishing characteristic of EV subtypes.
Compatibility
EVsure has demonstrated compatibility with EV samples enriched from size exclusion chromatography (SEC) and ultracentrifugation isolation methods.
EVsure is compatible with EV samples containing between 1×10^8 and 1×10^10 particles/mL. Unprocessed conditioned media is often very dilute and contains EVs in concentrations below this range. For this reason, we recommend isolating EVs from conditioned media and concentrating as necessary to ensure an adequate EV concentration.
Yes, EVsure has demonstrated compatibility with EVs enriched from human plasma.
EVsure is compatible with any luminescent plate reader.
EVsure is agnostic to sample storage conditions. EVsure measures the combined concentration of CD9, CD63, and CD81 tetraspanin-positive intact EVs present in the sample.
Use cases
You’re standing over a freezer box of isolated samples. Months of work went into them, and the experiments you’ve planned depend on a question you can’t skip: are there actually extracellular vesicles in these tubes, and are there enough to go on?
You already know this step matters. Before you can make claims about what your EVs do, you have to show they’re there and know how many you have. Everything that follows rests on it.
So you start weighing your options. There are plenty, and each one asks you to give something up.
You might reach for nanoparticle tracking analysis first, since it’s familiar and widely used. It gives you a concentration, but it counts every particle in the size range, not just EVs. Protein aggregates and debris end up in the tally too. It also takes a lot of hands-on time, and you’ve probably heard colleagues say the results can shift from run to run. When you get the number, how much do you trust it?
Nanoflow cytometry promises more specificity, but you know what it demands. The instrument is complex and takes specialized training to run well. Setup often turns into trial and error, and you may burn hours tuning before you get a usable run. Your results then depend on manual steps and on the fluorescent antibody you choose. In most protocols, a single antibody, labeled directly or detected with a fluorescent secondary, is what produces your signal. Every choice and every pipetting step is another chance for variability to creep in.
ELISA targets EV membrane proteins, so you get specificity, and the plate format gives you throughput. But the setup is time-consuming, and all those manual wash steps leave room for error. A small difference in technique between two people, or two days, can show up in your data.
Whichever way you go, you’re trading specificity, time, effort, and consistency against each other, and none of the options gives you all four.
That’s the gap EVsure was built to close.
EVsure’s Direct dual-Tetraspanin Epitope Capture Technology (DTECT) uses a pair of antibodies that bind different epitopes on each tetraspanin (CD9, CD63, and CD81). You only get a signal when both antibodies bind, so non-specific binding is minimized and your EV quantitation is highly specific. There are no wash steps and few hands-on steps, which removes much of the variability that creeps in at the bench. And with a 96-well format, you can run many samples at once and get results that are simply consistent.
So the next time you’re standing at that freezer box, you can get an answer you trust and move on to the science you set out to do.
It’s the end of the quarter, and you’re staring at your validation plan. Somewhere in the stack of documents is a table with three blank rows: limit of detection, limit of quantitation, linear range. Each of those numbers depends on a single question you have to answer with confidence: how many EVs are actually in these samples?
Down the hall, your manufacturing counterpart faces the same question from a different direction. Every lot of assay and every batch of EV-based control has to be tested before it ships, and each must perform to specification. If your teams can’t reliably count the EVs in a control, you can’t trust the control, and everything calibrated against it inherits that doubt.
So you both go looking for a method, and each option fits part of the job but not all of it.
Nanoparticle tracking analysis is the obvious first stop. It’s familiar and widely used. But it counts particles, not EVs, so debris and protein aggregates add to the total. It also needs close attention from an operator, and it runs one sample at a time. That’s manageable for a research project, but your development program generates hundreds of measurements, and your manufacturing line generates more every week. Then there’s the reputation for run-to-run inconsistency, which is a serious problem when your goal is a performance claim that has to hold up under scrutiny.
Nanoflow cytometry promises better specificity, but it brings its own demands. It’s complex and calls for specialized training. Your results depend on manual steps and on fluorescent antibody choices, each a source of variability. And while conventional flow cytometers can handle 96-well plates, nanoflow instruments analyze one sample at a time, so the throughput problem returns.
ELISA offers a way to scale. It targets EV membrane proteins, so it’s specific to EVs, and the plate format handles volume. But the set-up is slow, and the repeated manual washes let small differences between operators and days creep into your data. In a regulated environment, that kind of drift is exactly what your quality team works to eliminate.
By the time you’ve weighed every option, the picture is clear. Each method gives up something your work can’t afford to lose: specificity, scale, or consistency. The efficiency and precision that diagnostics demand are largely missing.
That’s the gap EVsure was built to close.
EVsure’s Direct dual-Tetraspanin Epitope Capture Technology (DTECT) uses paired antibodies that bind different epitopes on each tetraspanin (CD9, CD63, and CD81), which minimizes non-specific binding and makes your measurement highly specific to EVs. The workflow is no-wash with minimal hands-on steps, leaving less room for variability. And the 96-well format brings the throughput your development and manufacturing volumes require.
Now the blank rows in your validation table can finally be filled in with confidence. And for your manufacturing counterpart, lot release stops hinging on a number nobody fully trusts.
It’s the week before a dosing decision, and you’re looking at a batch record. Your product is a vial of engineered EVs, and the next step is to decide how much of it a patient should receive. Dose, potency, safety, efficacy: every one of those characteristics is expressed per EV. If the count is off, everything built on it is off too.
Down on the manufacturing floor, your quality counterpart is working through a different version of the same problem. Each batch has to meet specification before it can be released, and “meets specification” starts with knowing how many EVs the batch contains. A therapeutic that can’t be quantified reliably can’t be released with confidence, and a lot that can’t be compared to the last one raises questions no one wants to answer in front of a regulator.
So you both look for a method you can rely on, and each candidate solves one piece of the puzzle while leaving another open.
Nanoparticle tracking analysis is the familiar starting point. It reports particle concentration, but particles are not the same as EVs, and residual debris and protein aggregates in your therapeutic preparation count toward the total. It demands hours of hands-on attention and processes one sample at a time. That may be tolerable for a pilot study, but your development program multiplies the sample count with every formulation, time point, and stability study, and manufacturing multiplies it again with every batch. Add it’s reputation for run-to-run inconsistency, and the number on the screen becomes hard to defend.
Nanoflow cytometry promises more specificity, but at a cost. The instrument is complex, your operators need specialized training, and your results hinge on manual steps and the choice of fluorescent antibodies, each a potential source of variability. Conventional flow cytometers can read 96-well plates, but nanoflow instruments analyze a single sample at a time, so the throughput problem returns.
ELISA scales better. It targets EV membrane proteins, so the signal is specific to EVs, and the plate format handles volume. But the set-up is slow, and the repeated manual washes let small differences between operators and days seep into your data. For a product headed toward patients, that kind of variability is exactly what your teams work to remove.
After weighing every option, the pattern is hard to miss. Each method gives up something your work can’t spare: specificity, scale, or consistency. The efficiency and precision that therapeutic development and manufacturing require are largely out of reach.
That’s the gap EVsure was designed to close.
EVsure’s Direct dual-Tetraspanin Epitope Capture Technology (DTECT) uses paired antibodies that bind different epitopes on each tetraspanin (CD9, CD63, and CD81), minimizing non-specific binding and making your measurement highly specific to EVs. The workflow is no-wash with minimal hands-on steps, so there’s less opportunity for variability to enter. And the 96-well format delivers the throughput your development programs and manufacturing runs demand.
Now your dosing decision can rest on a number you trust. And for your quality counterpart, batch release rests on a measurement that holds up from lot to lot.
The EV-HIV assay is for research use only. It is not intended for use in diagnostic procedures.
EVsure is for research use only. It is not intended for use in diagnostic procedures.